Setting Library Coverage and MOI
The Short Answer
Target at least 500 cells per guide at every timepoint, use an MOI near 0.3 to keep most cells singly transduced, and sample enough cells at each harvest to represent every guide. The three numbers multiply into the scale of the experiment.
Table 1. The Arithmetic
| Parameter | Typical target | Why |
|---|---|---|
| Coverage per timepoint | ≥500 cells per guide | Sampling noise and dropout of rare guides |
| MOI | ≈0.3 | Most cells receive one integration; avoids double knockouts |
| Cells per harvest | Coverage × library size | Every guide must be represented in the sequenced sample |
| Library size | Library-dependent | Genome-wide libraries are large; focused libraries are small |
| Timepoints | ≥2 (early and late) | Distinguishes dropout from baseline skew |
Part 1 — Why Low MOI
At high MOI, a cell can receive two or more guides, which produces double knockouts and confounds the attribution of a phenotype to one gene. An MOI near 0.3 keeps the majority of transduced cells singly integrated, at the cost of a larger number of cells needed to achieve coverage.
The trade-off is scale. Lower MOI means more cells infected to reach the same coverage, which for a genome-wide library is a large number. That is why genome-wide screens are performed in well-plates at scale and why focused libraries are used when the question allows.
Part 2 — Sampling and Representation
The sample taken at each timepoint must represent every guide, which means the number of cells harvested must exceed the coverage target, not the number of cells plated. A common error is to seed at coverage and harvest a fixed fraction, which reduces representation progressively.
Reporting should state the coverage at each timepoint, not only at transduction, because selection reduces representation in a way that is itself informative — a guide that disappears early was lethal.
Table 2. Reporting Requirements
| Item | Why |
|---|---|
| Cells transduced and MOI achieved | Determines single-integration fraction |
| Coverage at each timepoint | Representation changes with selection |
| Library size and version | Hit lists are library-specific |
| Selection schedule | Determines which phenotypes are visible |
Part 3 — Where This Connects
The screen formats and analysis are in /genome-wide-crispr-screen-design, and the platform description is at /platforms/crispr-screening. The model qualification requirements are in /cell-line-selection-authentication.
Contact EDITGENE to request a project consultation or a quote.
Scientific scope and validation note
Coverage targets are conventions, and the appropriate value depends on the expected effect size and on the library. A screen designed to detect small effects needs more coverage than the convention.
Selected references for further reading
- • Hart T, Chandrashekhar M, Aregger M, et al. High-resolution CRISPR screens reveal fitness genes and genotype-specific cancer liabilities. Cell. 2015;163:1515–1526.
- • Sanson KR, Hanna RE, Hegde M, et al. Optimized libraries for CRISPR–Cas9 genetic screens with multiple modalities. Nature Communications. 2018;9:5416.
- • Li W, Xu H, Xiao T, et al. MAGeCK enables robust identification of essential genes from genome-scale CRISPR/Cas9 knockout screens. Genome Biology. 2014;15:554.
Scientific interpretation and experimental design
- • Compute the scale from coverage, MOI and library size before ordering anything.
- • Keep MOI near 0.3 to avoid double knockouts.
- • Harvest more cells than the coverage target, and report coverage per timepoint.
- • State the library version; hit lists are library-specific.
Related Services
Related Products
| Product name | Cat.No. | Species | Gene ID | |
|---|---|---|---|---|
| PBRM1 Knockout A-549 Cell Line | EDJ0001-K01 | Human | 55193 | Details Get a Quote |
| YTHDC1 Knockout A-549 Cell Line | EDC07652 | Human | 91746 | Details Get a Quote |
| TP53 Knockout HCT 116 Cell Line | EDC07854 | Human | 7157 | Details Get a Quote |
| Sirt2 Knockout MH-S Cell Line | EDJ-KQ78173 | Mouse | 64383 | Details Get a Quote |
| TFE3 Knockout KGN Cell Line | EDJ-KQ48 | Human | 7030 | Details Get a Quote |
| Stub1 Knockout MB49 Cell Line | EDJ-KQ53 | Mouse | 56424 | Details Get a Quote |
| ARID1A Knockout SNK-6 Cell Line | EDJ-KQ64 | Human | 8289 | Details Get a Quote |
| Tet1 Knockout Kupffer Cell Line | EDJ-KQ88 | Mouse | 52463 | Details Get a Quote |
| NR1H3 Knockout HEK293T Cell Line | EDJ-KQ109 | Human | 10062 | Details Get a Quote |
| NR1H2 Knockout HEK293T Cell Line | EDJ-KQ110 | Human | 7376 | Details Get a Quote |
| RPS6KB2 Knockout HEK293 Cell Line | EDJ-KQ125 | Human | 6199 | Details Get a Quote |
| SMAD6 Knockout HEK293 Cell Line | EDJ-KQ126 | Human | 4091 | Details Get a Quote |
| JUN Knockout HEK293 Cell Line | EDJ-KQ176 | Human | 3725 | Details Get a Quote |
| JUN Knockout HEK293T Cell Line | EDJ-KQ184 | Human | 3725 | Details Get a Quote |
| ALKBH5 Knockout HEK293 Cell Line | EDJ-KQ186 | Human | 54890 | Details Get a Quote |
- 1
- 2
- ...
- Next Page »