Fitting Drug Response Curves
The Short Answer
Fit a four-parameter logistic where the data support it, report the IC50 with a confidence interval, and report the top and bottom plateaus and the Hill slope. Where the curve does not plateau, report the concentration range tested instead of a single number.
Table 1. What Each Parameter Reports
| Parameter | Reports | Why it matters |
|---|---|---|
| Top plateau | Response at zero dose | Normalisation and assay quality |
| Bottom plateau | Maximum effect achieved | Whether the drug saturates |
| IC50 | Concentration at half-maximal effect | Only comparable between curves with similar shape |
| Hill slope | Steepness | Steep curves indicate cooperative or threshold behaviour |
| Confidence interval | Precision of the estimate | A point estimate without it is not interpretable |
Part 1 — When IC50 Comparison Fails
Two curves with different bottom plateaus have different half-maximal points even if their potency is identical. Comparing IC50s across such curves compares the fitted shapes rather than the drugs. Where the plateaus differ, the informative comparison is the effect at a defined concentration, or the area under the curve, not the IC50.
The second failure is incomplete curves. If the tested range does not reach the bottom plateau, the IC50 is extrapolated, and a small change in the highest dose changes it substantially. Reporting the range and the effect achieved is more honest than a number derived from an extrapolation.
Part 2 — Normalisation and Replicates
Normalisation to untreated control defines the top plateau, and normalisation to a positive control defines the bottom. Both choices affect the fitted parameters, and both belong in the methods. Where a positive control is not available, the bottom plateau is estimated rather than defined.
Technical replicates belong in the fit as a single curve per biological replicate; fitting each technical replicate separately and averaging the IC50s produces a value with the wrong variance. The unit of analysis is the biological replicate.
Table 2. Reporting Checklist
| Item | Requirement |
|---|---|
| Model and constraints | Four-parameter logistic, or the reduced model used |
| Normalisation | Untreated and positive controls stated |
| Parameters | IC50 with confidence interval; top, bottom, Hill slope |
| Replicate structure | Curves fitted per biological replicate |
| Range tested | Stated; required when the curve is incomplete |
Part 3 — Where This Connects
The assay design that produces the data is in /migration-invasion-assay for motility endpoints and in /parp-inhibitor-sensitivity for sensitivity endpoints. The combination-scoring problem is in /combination-therapy-synergy.
Contact EDITGENE to request a project consultation or a quote.
Scientific scope and validation note
Fitted parameters are model-dependent. A different model gives different numbers from the same data, which is why the model belongs in the methods and in the figure legend.
Selected references for further reading
- • Yadav B, Wennerberg K, Aittokallio T, Tang J. Searching for drug synergy in complex dose–response landscapes using an interaction potency model. Computational and Structural Biotechnology Journal. 2015;13:504–513.
- • Meyers RM, Bryan JG, McFarland JM, et al. Computational correction of copy number effect improves specificity of CRISPR–Cas9 essentiality screens in cancer cells. Nature Genetics. 2017;49:1779–1784.
Scientific interpretation and experimental design
- • Report IC50 with a confidence interval and the fitted plateaus.
- • Do not compare IC50s when the bottom plateaus differ.
- • Report the range tested when the curve does not plateau.
- • Fit one curve per biological replicate; the unit of analysis is the replicate.
Related Services
Related Products
| Product name | Cat.No. | Species | Gene ID | |
|---|---|---|---|---|
| PBRM1 Knockout A-549 Cell Line | EDJ0001-K01 | Human | 55193 | Details Get a Quote |
| YTHDC1 Knockout A-549 Cell Line | EDC07652 | Human | 91746 | Details Get a Quote |
| TP53 Knockout HCT 116 Cell Line | EDC07854 | Human | 7157 | Details Get a Quote |
| Sirt2 Knockout MH-S Cell Line | EDJ-KQ78173 | Mouse | 64383 | Details Get a Quote |
| TFE3 Knockout KGN Cell Line | EDJ-KQ48 | Human | 7030 | Details Get a Quote |
| Stub1 Knockout MB49 Cell Line | EDJ-KQ53 | Mouse | 56424 | Details Get a Quote |
| ARID1A Knockout SNK-6 Cell Line | EDJ-KQ64 | Human | 8289 | Details Get a Quote |
| Tet1 Knockout Kupffer Cell Line | EDJ-KQ88 | Mouse | 52463 | Details Get a Quote |
| NR1H3 Knockout HEK293T Cell Line | EDJ-KQ109 | Human | 10062 | Details Get a Quote |
| NR1H2 Knockout HEK293T Cell Line | EDJ-KQ110 | Human | 7376 | Details Get a Quote |
| RPS6KB2 Knockout HEK293 Cell Line | EDJ-KQ125 | Human | 6199 | Details Get a Quote |
| SMAD6 Knockout HEK293 Cell Line | EDJ-KQ126 | Human | 4091 | Details Get a Quote |
| JUN Knockout HEK293 Cell Line | EDJ-KQ176 | Human | 3725 | Details Get a Quote |
| JUN Knockout HEK293T Cell Line | EDJ-KQ184 | Human | 3725 | Details Get a Quote |
| ALKBH5 Knockout HEK293 Cell Line | EDJ-KQ186 | Human | 54890 | Details Get a Quote |
- 1
- 2
- ...
- Next Page »