Tumor Dependency and Editing Strategy Self-Assessment Tool
What This Tool Is
Most failed editing projects fail before the bench. A question is posed in a form that no experiment can answer, or a model is chosen that cannot express the phenotype, or a readout is chosen that reports a different variable. The assessment is a short interview that surfaces those mismatches while they are still cheap to fix.
It takes five inputs, each of which is a statement about your project rather than a preference: the strength of the genotype evidence, the model system, the phenotype you need to explain, the resolution your question requires, and the readout you intend to use. The output is a one-page decision record: the claim your current evidence supports, the specific gap between that claim and your question, and the smallest experiment that would close it.
The design principle is that the tool never returns a recommendation it cannot justify from the inputs. If the genotype is unconfirmed, no editing strategy is proposed, because the strategy depends on which allele is present. If the phenotype is not measurable in the chosen model, the tool says so rather than proposing a more efficient protocol for an unanswerable question.
Part 1 — The Five Inputs
Each input has levels, and each level changes what the rest of the assessment can conclude. The levels are deliberately coarse: the purpose is to force a decision, not to score nuance.
Table 1. The Five Inputs and What Each Level Changes
| Input | Levels | What the level changes |
|---|---|---|
| Genotype evidence | Variant call only / allelic fraction measured / biallelic loss or amplification confirmed / protein or function confirmed | Determines whether a perturbation can be attributed to the lesion at all |
| Model system | Cell line / isogenic pair / organoid / primary cells / in vivo | Determines which phenotypes are expressible |
| Phenotype question | Growth / death / state change / differentiation / interaction with a compartment | Determines the readout and the time window |
| Resolution required | Gene / allele / transcript / protein / state | Determines the perturbation tool |
| Readout | Viability / clonogenic / imaging / transcript / protein / functional assay | Determines what the result can be said to show |
The order matters. A high-resolution question posed on a low-evidence genotype produces a precise answer about the wrong thing, which is worse than a coarse answer about the right thing. The tool therefore evaluates the inputs in this order and stops at the first one that cannot support the question.
Part 2 — Reading the Output
The output has three lines. The first states the strongest claim the current evidence supports, in the form in which it could be published. The second states the gap. The third states the minimum next experiment, including what would count as a negative result.
That third element is the one most planning documents omit. An experiment without a pre-defined negative outcome cannot fail, and an experiment that cannot fail produces no information. Writing the negative result in advance is also what makes a later decision to change strategy defensible.
Table 2. Evidence Tiers and the Claim Each One Allows
| Evidence held | Claim allowed | Claim not allowed |
|---|---|---|
| Variant call in a database | The variant is present in this model, subject to confirmation | The pathway is activated; the gene is lost |
| Allelic fraction plus copy number | The lesion is present at a stated dosage | The protein is absent or inactive |
| Protein or function confirmed | The gene product is lost or altered | The loss causes the phenotype |
| Perturbation with an isogenic control | The phenotype depends on the lesion in this background | The dependency is general across lineages |
| Perturbation across backgrounds | The dependency is reproducible across the backgrounds tested | The dependency is universal |
Part 3 — Where the Assessment Is Weak
Three failure modes are common enough to state plainly. The first is answering the questions in the order that produces the desired output: choosing the model first and then describing the phenotype to fit it. The second is treating a documented dependency as a measured one. The third is confusing the resolution of a tool with the resolution of an experiment: a base editor can change one base, but the validation may still be a bulk assay that cannot see allele-level outcomes.
Table 3. Input Errors and Their Downstream Cost
| Input error | What it produces | Cost |
|---|---|---|
| Genotype assumed, not measured | A perturbation attributed to the wrong lesion | The whole project, discovered late |
| Model not checked for the phenotype | A negative result that is uninterpretable | One to three months |
| Readout at the wrong resolution | A confident conclusion at the wrong level | Reagent and validation repeat |
| No pre-defined negative result | An experiment that cannot fail | Continued investment without information |
Used properly, the assessment is a record rather than a score. It is most useful when it is completed before a project starts and again when a result is in hand, because the second pass usually reveals that the question moved during the work.
Where This Connects
The evidence tiers used here are defined in /oncogenes-tumor-suppressors, and the resolution ladder is expanded in /kras-g12c-vs-g12d-editing and /heterozygous-deletion-model. Model selection is covered in /cell-line-selection-authentication and /organoid-pdo-models. For the execution side of the same decisions, see /services/tumor-knockout-cell-lines and /services/allele-specific-editing.
Related Services
Related Products
| Product name | Cat.No. | Species | Gene ID | |
|---|---|---|---|---|
| PBRM1 Knockout A-549 Cell Line | EDJ0001-K01 | Human | 55193 | Details Get a Quote |
| YTHDC1 Knockout A-549 Cell Line | EDC07652 | Human | 91746 | Details Get a Quote |
| TP53 Knockout HCT 116 Cell Line | EDC07854 | Human | 7157 | Details Get a Quote |
| Sirt2 Knockout MH-S Cell Line | EDJ-KQ78173 | Mouse | 64383 | Details Get a Quote |
| TFE3 Knockout KGN Cell Line | EDJ-KQ48 | Human | 7030 | Details Get a Quote |
| Stub1 Knockout MB49 Cell Line | EDJ-KQ53 | Mouse | 56424 | Details Get a Quote |
| ARID1A Knockout SNK-6 Cell Line | EDJ-KQ64 | Human | 8289 | Details Get a Quote |
| Tet1 Knockout Kupffer Cell Line | EDJ-KQ88 | Mouse | 52463 | Details Get a Quote |
| NR1H3 Knockout HEK293T Cell Line | EDJ-KQ109 | Human | 10062 | Details Get a Quote |
| NR1H2 Knockout HEK293T Cell Line | EDJ-KQ110 | Human | 7376 | Details Get a Quote |
| RPS6KB2 Knockout HEK293 Cell Line | EDJ-KQ125 | Human | 6199 | Details Get a Quote |
| SMAD6 Knockout HEK293 Cell Line | EDJ-KQ126 | Human | 4091 | Details Get a Quote |
| JUN Knockout HEK293 Cell Line | EDJ-KQ176 | Human | 3725 | Details Get a Quote |
| JUN Knockout HEK293T Cell Line | EDJ-KQ184 | Human | 3725 | Details Get a Quote |
| ALKBH5 Knockout HEK293 Cell Line | EDJ-KQ186 | Human | 54890 | Details Get a Quote |
- 1
- 2
- ...
- Next Page »