PDX and In Vivo Models

A patient-derived xenograft is the only system that combines a patient's tumour with an in vivo environment. It is also the system with the strongest selection at every step.

What This Page Covers

The cluster page compares model systems and lists the variance sources. This page covers the in vivo decision and the PDX-specific limitations: what engraftment selects for, what changes on passage, and what the model can predict.

Part 1 — Engraftment Is a Selection

Not every tumour grows in a mouse. Engraftment favours aggressive tumours, particular histologies and particular host strains, so a PDX collection is a biased sample of the tumours it was derived from. That bias is why PDX panels over-represent responsive and aggressive disease.

Reporting the take rate per model, rather than pooled, makes the bias visible. A study that reports a pooled take rate and then analyses only the models that grew has described a selected population without saying so.

Part 2 — What Changes on Passage

Two changes occur reliably. Mouse stroma progressively replaces human stroma, which alters signalling and drug delivery; and clonal composition drifts, because the clones that grow fastest in a mouse are not the clones that dominated the patient's tumour.

Early-passage models are therefore preferred for any question about the patient, and the passage number belongs in the result. Where a model has been carried for many passages, it is a model of a mouse-adapted tumour.

Table 1. PDX Limitations and Their Consequences

LimitationConsequenceMitigation
Engraftment biasPanel over-represents aggressive diseaseReport take rate per model
Stromal replacementAltered signalling and drug deliveryUse early passage; state passage
Clonal driftModel diverges from the donor tumourEarly passage; genomic comparison with donor
ImmunodeficiencyNo adaptive immune compartmentUse a humanised or syngeneic system for immune questions

Part 3 — Choosing the In Vivo System

Four systems answer four different questions. A cell-line xenograft tests a defined genome with a dosing schedule, without immunity. A PDX tests a patient's tumour, with the limitations above. A syngeneic model tests immunocompetent biology with mouse genetics. A genetically engineered model tests initiation and progression in situ at low throughput.

The decision usually reduces to whether immunity is part of the hypothesis and whether the patient's genome is part of the question. If neither, a cell-line xenograft is cheaper and more interpretable.

Table 2. In Vivo Systems and Their Questions

SystemQuestionCannot answer
Cell-line xenograftDoes this genome respond to this schedule?Immunity; human stroma
PDXDoes this patient's tumour respond?Immunity; clonal stability on passage
SyngeneicHow does the immune system shape the response?Human genetics
GEMMHow does the tumour initiate and progress in situ?Throughput; defined lesion control

Table 3. Reporting Checklist

ItemRequirement
Take ratePer model, not pooled
Passage at useStated for every experiment
Donor comparisonGenomic or histological match
Host strain and sexReported
Stromal statusHuman or murine, where known

Part 4 — Where This Connects

The timeline and cost question is in /pdx-timeline-cost, and the model comparison is in /tumor-models-functional-genomics. The immune-compartment requirement is in /tumor-microenvironment-immunotherapy.

Contact EDITGENE to request a project consultation or a quote.

Scientific scope and validation note

PDX predictivity is established at the cohort level for some tumour types and is weaker for individual patients. A PDX result is evidence about a model derived from a patient, not a prediction of that patient's outcome.

Selected references for further reading

  • • Gao H, Korn JM, Ferretti S, et al. High-throughput screening using patient-derived tumor xenografts to predict clinical trial drug response. Nature Medicine. 2015;21:1318–1325.
  • • Ben-David U, Siranosian B, Ha G, et al. Genetic and transcriptional evolution alters cancer cell line drug response. Nature. 2018;560:325–330.
  • • Drost J, Clevers H. Organoids in cancer research. Nature Reviews Cancer. 2018;18:407–418.

Scientific interpretation and experimental design

  • • Report take rate per model; pooled rates hide the selection.
  • • State the passage number; stroma and clones change.
  • • Use a syngeneic or humanised system when immunity is in the hypothesis.
  • • Treat PDX predictivity as cohort-level evidence, not an individual prediction.

Related Products

Product name Cat.No. Species Gene ID
PBRM1 Knockout A-549 Cell Line EDJ0001-K01 Human 55193 Details Get a Quote
YTHDC1 Knockout A-549 Cell Line EDC07652 Human 91746 Details Get a Quote
TP53 Knockout HCT 116 Cell Line EDC07854 Human 7157 Details Get a Quote
Sirt2 Knockout MH-S Cell Line EDJ-KQ78173 Mouse 64383 Details Get a Quote
TFE3 Knockout KGN Cell Line EDJ-KQ48 Human 7030 Details Get a Quote
Stub1 Knockout MB49 Cell Line EDJ-KQ53 Mouse 56424 Details Get a Quote
ARID1A Knockout SNK-6 Cell Line EDJ-KQ64 Human 8289 Details Get a Quote
Tet1 Knockout Kupffer Cell Line EDJ-KQ88 Mouse 52463 Details Get a Quote
NR1H3 Knockout HEK293T Cell Line EDJ-KQ109 Human 10062 Details Get a Quote
NR1H2 Knockout HEK293T Cell Line EDJ-KQ110 Human 7376 Details Get a Quote
RPS6KB2 Knockout HEK293 Cell Line EDJ-KQ125 Human 6199 Details Get a Quote
SMAD6 Knockout HEK293 Cell Line EDJ-KQ126 Human 4091 Details Get a Quote
JUN Knockout HEK293 Cell Line EDJ-KQ176 Human 3725 Details Get a Quote
JUN Knockout HEK293T Cell Line EDJ-KQ184 Human 3725 Details Get a Quote
ALKBH5 Knockout HEK293 Cell Line EDJ-KQ186 Human 54890 Details Get a Quote
Contact Us
*
*
*
How did you hear about us: