A pooled screen is a selection experiment with a sequencing readout. What it can tell you is bounded by the selection you apply, not by the size of the library.

What This Platform Does

The platform runs pooled loss-of-function and gain-of-function selections in cell lines, organoids and primary cultures, in four formats: dropout, enrichment, reporter-activated sorting, and combinatorial perturbation. Each format answers a different kind of question, and the difference is not the library but the selection pressure applied between the first and last timepoint.

The design principles behind a screen are set out in /genome-wide-crispr-screen-design and are not repeated here. This page describes what is executed, what is measured, and what is handed over, because those three things determine what a customer can do with the result.

Table 1. Four Screen Formats and the Question Each One Answers

FormatSelection appliedQuestion answeredTypical readout
DropoutCompetitive growth over 14 to 21 daysWhich genes are required for growth in this contextGuide abundance change between arms
EnrichmentDrug, immune pressure or a metabolic stressWhich losses confer survival or resistanceEnrichment of guides in the treated arm
Reporter-activated sortingFACS on a transcriptional or signalling reporterWhich genes regulate a specific outputGuide enrichment in sorted bins
CombinatorialPaired guides or a modifier libraryWhich pairs interact, including synthetic lethalityDouble-guide representation and interaction score

Format selection is the main design decision, and it is usually made too late. A dropout screen in a line that grows slowly will be dominated by noise from the first timepoint. An enrichment screen with a single drug concentration will recover efflux pumps and nothing else. Both are format errors, not analysis errors.

Part 1 — The Deliverable Package

A screen that ends with a ranked gene list is not finished. The package includes the library definition, per sample counts, coverage statistics at each timepoint, the normalisation and model used, effect sizes with confidence intervals, and a validation set run independently of the discovery arm.

Table 2. What Is Delivered and Why Each Item Is Needed

ItemContentPurpose
Library definitionGuide sequences, target mapping, control guidesAllows the analysis to be reproduced or reanalysed
Coverage reportCells and reads per guide at each timepointStates the sensitivity of the screen
Count matrixRaw and normalised counts per samplePermits an independent model
Ranked tableEffect size, confidence interval, guide-level concordanceSeparates effect from significance
Quality summaryControl-guide behaviour, replicate correlation, essential-gene recoveryStates whether the run behaved as expected
Validation armIndependent reagents, separate experimentDistinguishes a hit from a library artefact

Part 2 — Quality Gates

Three gates are applied before a hit list is released, and a run that fails a gate is reported as failed rather than delivered with a caveat. The gates are deliberately conservative, because a screen that is 80% reliable produces a hit list that is 20% wrong and impossible to triage.

Table 3. Gates Applied Before Release

GateCriterionIf it fails
CoverageAt least 500 cells per guide at every timepointThe timepoint is extended or the screen is redesigned
Dynamic rangeEssential-gene guides separate from non-targeting controlsThe selection was too weak to detect a dependency
ConcordanceGuides for the same gene agree beyond chanceThe gene is reported as unresolved, not as a hit
Replicate behaviourBiological replicates correlate above the pre-set thresholdThe run is repeated rather than pooled

Part 3 — When a Screen Is the Wrong Tool

A screen measures the effect of a perturbation on a population under one selection. It does not measure mechanism, and it cannot resolve a phenotype that the population does not express. Several common questions are therefore better answered another way, and saying so is part of the service.

Table 4. Questions Better Answered Without a Screen

QuestionWhy a screen is weak hereBetter approach
Does this specific gene matter in this modelA single-gene answer does not need a genome-wide libraryArrayed perturbation with an isogenic control
How does the pathway respond over minutesPooled selection integrates over daysLive imaging or phospho-readout in a time course
What is the mechanism of a known dependencyA screen gives necessity, not mechanismInteraction assay, localisation and rescue
Which combination is synergisticPairwise space is too large for a genome-wide libraryA focused modifier library with a defined synergy model

The most frequent mismatch is a mechanism question posed as a screen. It produces a list of genes that are required for growth under the condition, which is true and unrelated to the mechanism the project needs.

Where This Connects

Design parameters, library choice and analysis models are in /genome-wide-crispr-screen-design; coverage and multiplicity arithmetic are in /library-coverage-moi. Downstream validation of a hit follows the evidence ladder in /oncogenes-tumor-suppressors, and resistance selections are described in /services/resistance-models. Related capability pages are /platforms/single-cell-spatial and /platforms/high-content-imaging.

Related Products

Product name Cat.No. Species Gene ID
PBRM1 Knockout A-549 Cell Line EDJ0001-K01 Human 55193 Details Get a Quote
YTHDC1 Knockout A-549 Cell Line EDC07652 Human 91746 Details Get a Quote
TP53 Knockout HCT 116 Cell Line EDC07854 Human 7157 Details Get a Quote
Sirt2 Knockout MH-S Cell Line EDJ-KQ78173 Mouse 64383 Details Get a Quote
TFE3 Knockout KGN Cell Line EDJ-KQ48 Human 7030 Details Get a Quote
Stub1 Knockout MB49 Cell Line EDJ-KQ53 Mouse 56424 Details Get a Quote
ARID1A Knockout SNK-6 Cell Line EDJ-KQ64 Human 8289 Details Get a Quote
Tet1 Knockout Kupffer Cell Line EDJ-KQ88 Mouse 52463 Details Get a Quote
NR1H3 Knockout HEK293T Cell Line EDJ-KQ109 Human 10062 Details Get a Quote
NR1H2 Knockout HEK293T Cell Line EDJ-KQ110 Human 7376 Details Get a Quote
RPS6KB2 Knockout HEK293 Cell Line EDJ-KQ125 Human 6199 Details Get a Quote
SMAD6 Knockout HEK293 Cell Line EDJ-KQ126 Human 4091 Details Get a Quote
JUN Knockout HEK293 Cell Line EDJ-KQ176 Human 3725 Details Get a Quote
JUN Knockout HEK293T Cell Line EDJ-KQ184 Human 3725 Details Get a Quote
ALKBH5 Knockout HEK293 Cell Line EDJ-KQ186 Human 54890 Details Get a Quote
Contact Us
*
*
*
How did you hear about us: