Delivery Standards and QC Whitepaper

A delivered model is a set of claims. This page states which claims are verified, by what method, against what criterion, and what happens when a criterion is not met.

Scope

The standard applies to edited cell lines, reporter lines, resistant models and organoid lines. It defines the minimum verification for each, the documentation that must accompany a shipment, and the conditions under which a previously verified property must be re-checked. It does not define the scientific design of an experiment; that is the customer's responsibility and ours jointly.

Table 1. Release Criteria by Category

CategoryMethodCriterionOn failure
IdentityShort tandem repeat profiling against the reference profileMatch at all markers, no mixtureLine not released; source re-checked
SterilityMycoplasma testing by nucleic acid amplificationNegativeDiscarded; batch investigated
EditingAmplicon sequencing plus digital PCR for allele fractionIntended edit present at the specified levelClone not released; alternative clones screened
Off-target reviewIn silico prediction plus targeted sequencing of the top sitesNo unexpected edit at a reported siteReported as a finding; customer decides
Protein consequenceWestern blot or flow with a validated antibodyReduced or absent where the design predicts lossReported as a partial phenotype, not as a failure
Genomic stabilityCopy-number profile compared with the parental lineNo unexplained change at the target locusReported; clone flagged

Part 1 — What the Documentation Contains

The documentation is written so that a reader who has never seen the project can reconstruct what was done and decide how far to trust it. It is not a marketing document, and it includes the parts that did not work.

  • • Line provenance, authentication result and passage number at freezing.
  • • Guide or construct sequences, delivery method and selection conditions.
  • • Per-allele genotype with the method used and the allele fractions observed.
  • • Protein-level result and the antibody used, including its validation status.
  • • Off-target prediction output and which sites were sequenced.
  • • Growth data, morphology images and any karyotype or copy-number finding.
  • • A statement of what was not tested.

Part 2 — Re-verification Triggers

Verification has a shelf life. The following events invalidate a previous result and require a defined check before the model is used in a regulated or publication-bound context.

Table 2. Events That Require Re-verification

EventRe-check requiredReason
More than a defined number of passages since releaseIdentity and editingDrift and selection in culture
Thaw from a new stockIdentity, sterilityHandling errors and cross-contamination
Change of medium or serum batchGrowth and, for reporters, baseline signalMedium changes the phenotype
Any genetic manipulation after releaseEditing and off-targetA second edit invalidates the first genotype
Unexplained change in growth or morphologyIdentity first, then genotypeContamination or drift

Part 3 — Limits of the Standard

Three limits are stated openly because a standard that overclaims is worse than no standard. First, off-target review is targeted, not whole-genome; it reduces risk and does not eliminate it. Second, protein-level verification depends on antibody quality, and an antibody that has not been validated against a knockout cannot support a loss claim. Third, functional verification is only performed where an assay exists, and its absence is recorded rather than implied.

Where a customer requires whole-genome sequencing or a functional assay that does not yet exist, that is a separate scope with its own feasibility assessment. It is not quietly included under a general quality claim.

Table 3. Claims the Standard Does and Does Not Support

ClaimSupportedNot supported
The line is what it says it isYes, by STR and documentationThat it is free of all possible contamination
The intended edit is presentYes, at allele levelThat no other edit exists anywhere in the genome
The protein is lostYes, where a validated antibody was usedThat residual truncated protein is absent in every assay
The model behaves as expectedOnly where a functional assay was runThat it will behave the same in the customer's hands

Where This Connects

Verification levels for knockout lines are in /services/tumor-knockout-cell-lines, and the allele-level detail is in /heterozygous-deletion-model. Off-target reasoning is in /crispr-off-cancer and /ddr-genome-instability. For commercial comparison, see /comparison/tumor-model-providers.

Related Products

Product name Cat.No. Species Gene ID
PBRM1 Knockout A-549 Cell Line EDJ0001-K01 Human 55193 Details Get a Quote
YTHDC1 Knockout A-549 Cell Line EDC07652 Human 91746 Details Get a Quote
TP53 Knockout HCT 116 Cell Line EDC07854 Human 7157 Details Get a Quote
Sirt2 Knockout MH-S Cell Line EDJ-KQ78173 Mouse 64383 Details Get a Quote
TFE3 Knockout KGN Cell Line EDJ-KQ48 Human 7030 Details Get a Quote
Stub1 Knockout MB49 Cell Line EDJ-KQ53 Mouse 56424 Details Get a Quote
ARID1A Knockout SNK-6 Cell Line EDJ-KQ64 Human 8289 Details Get a Quote
Tet1 Knockout Kupffer Cell Line EDJ-KQ88 Mouse 52463 Details Get a Quote
NR1H3 Knockout HEK293T Cell Line EDJ-KQ109 Human 10062 Details Get a Quote
NR1H2 Knockout HEK293T Cell Line EDJ-KQ110 Human 7376 Details Get a Quote
RPS6KB2 Knockout HEK293 Cell Line EDJ-KQ125 Human 6199 Details Get a Quote
SMAD6 Knockout HEK293 Cell Line EDJ-KQ126 Human 4091 Details Get a Quote
JUN Knockout HEK293 Cell Line EDJ-KQ176 Human 3725 Details Get a Quote
JUN Knockout HEK293T Cell Line EDJ-KQ184 Human 3725 Details Get a Quote
ALKBH5 Knockout HEK293 Cell Line EDJ-KQ186 Human 54890 Details Get a Quote
Contact Us
*
*
*
How did you hear about us: