Custom Metabolic Reporter Cell Lines

There is no glycolysis reporter. There are sensors for nodes, and each reports a node.

What we build

ArchitectureSensor examplesWhat it reportsResponse time
GlucoseFRET glucose sensor; single-fluorophore glucose sensorIntracellular free glucoseSeconds
LactateFRET lactate sensorIntracellular lactateSeconds
NAD(H) redoxRatiometric redox sensorNAD⁺/NADH ratioSeconds–minutes
ATP/ADPFRET ATP sensor; ratiometric ATP/ADP sensorAdenylate ratioSeconds
Lipid dropletDroplet-targeted fluorescent proteinDroplet association and numberMinutes–hours
TranscriptionalPathway-responsive promoter driving a fluorescent proteinTranscriptional outputHours

Important distinction. A sensor reports the concentration or ratio it was engineered to bind. Converting that into a flux requires a model, and usually a second measurement. A glucose sensor falls when consumption rises and also when supply falls, and the sensor cannot tell you which.

The engineering decision that matters

DecisionOptionsConsequence
AffinityKd matched to the physiological rangeToo high: the sensor buffers the analyte; too low: no dynamic range
Ratiometric or single-channelRatiometricSingle-channel is confounded by expression level and focus
LocalisationCytosolic, mitochondrial, nuclearWhole-cell sensors average compartments that differ several-fold
Expression levelLow, single-copyHigh expression perturbs the pathway it measures
PromoterEndogenous locus or constitutiveConstitutive is easier; endogenous avoids overexpression artefacts

The affinity decision is the one that most often goes wrong. A high-affinity glucose sensor expressed at high level acts as a glucose sink, lowering the free concentration it is trying to report. The result is a sensor that changes the biology and reports the change.

Caveat on GFP-based sensors. Most green fluorescent protein derivatives are pH-sensitive, and glycolytic flux acidifies the cytosol. A sensor readout that tracks pH will look like a metabolic response. We test pH sensitivity by clamping intracellular pH across the physiological range and reporting the artefact.

QC before delivery

TestThresholdMethod
Dynamic range≥ 2-fold across the physiological rangePerfusion with calibrated analyte
Kd in the intended rangeWithin 0.3–3× the expected physiological concentrationDose–response in permeabilised cells
pH sensitivityStated as a percentage per 0.1 pH unitNH₄Cl pulse or nigericin clamp
Response timeReported as t½Rapid perfusion
OrthogonalityBasal OCR, ECAR and growth within 15% of parentalParallel assay
Clonal stabilityStable signal to passage 10Serial passage
LocalisationConfirmed by imagingConfocal

The fifth row is the one clients most often skip and the one that invalidates a dataset: a sensor line whose basal metabolism differs from the parental line cannot be compared with any published value from that background.

What you receive

  • • Two independent clones, expanded and mycoplasma-tested.
  • • A validation report with the seven QC items above, including the raw calibration traces.
  • • Parental and sensor lines banked at the same passage.
  • • Optional: lentiviral transfer vector, or the same sensor in a second background.

What we do not promise

  • • That the sensor measures flux. It measures a node; the interpretation is the experimenter's.
  • • That the dynamic range transfers to your medium. Serum, glucose concentration and pyruvate change the baseline; we report the range in our conditions and re-validate on request.
  • • That a clone behaves like the pool. Clonal selection changes expression and sometimes phenotype; we report basal metabolism for each clone.
  • • That a transcriptional reporter is fast. Promoter-based readouts lag by hours and cannot resolve a transient response.

Turnaround

StageWorking days
Vector construction10–15
Transduction and selection10–14
Single-cell cloning14–21
QC and banking10–14

Total 8–12 weeks, depending on the background and whether a second sensor must be combined.

What we need from you

  1. The analyte and the compartment.
  2. The cell background, with mycoplasma status and passage.
  3. The expected physiological range, or the condition you need to resolve.
  4. Whether the readout is imaging, plate reader or flow — this decides ratiometric versus single-channel.

Where this connects

  • • Glucose pillar supplies the reason a glucose sensor is not a flux measurement.
  • • Mitochondrial pillar supplies the redox and ATP sensor interpretation rules.
  • • The self-assessment asks whether the readout type matches the claim; a sensor line is a node readout, and the claim should be written accordingly.

Selected references for further reading

  • • San Martín A, et al. A genetically encoded FRET lactate sensor and its use to detect the Warburg effect in single cancer cells. PLOS ONE. 2013;8:e57712.
  • • Tantama M, Hung YP, Yellen G. Imaging intracellular pH in live cells with a genetically encoded red fluorescent protein sensor. Journal of the American Chemical Society. 2011;133:10034–10037.
  • • Zhao Y, et al. SoNar, a highly responsive NAD⁺/NADH sensor, allows high-throughput metabolic screening of anti-tumor agents. Cell Metabolism. 2015;21:777–789.
  • • Lobas MA, et al. A genetically encoded single-wavelength sensor for imaging cytosolic and cell surface ATP. Nature Communications. 2019;10:711.

Related Products

Product name Cat.No. Species Gene ID
PBRM1 Knockout A-549 Cell Line EDJ0001-K01 Human 55193 Details Get a Quote
YTHDC1 Knockout A-549 Cell Line EDC07652 Human 91746 Details Get a Quote
TP53 Knockout HCT 116 Cell Line EDC07854 Human 7157 Details Get a Quote
Sirt2 Knockout MH-S Cell Line EDJ-KQ78173 Mouse 64383 Details Get a Quote
TFE3 Knockout KGN Cell Line EDJ-KQ48 Human 7030 Details Get a Quote
Stub1 Knockout MB49 Cell Line EDJ-KQ53 Mouse 56424 Details Get a Quote
ARID1A Knockout SNK-6 Cell Line EDJ-KQ64 Human 8289 Details Get a Quote
Tet1 Knockout Kupffer Cell Line EDJ-KQ88 Mouse 52463 Details Get a Quote
NR1H3 Knockout HEK293T Cell Line EDJ-KQ109 Human 10062 Details Get a Quote
NR1H2 Knockout HEK293T Cell Line EDJ-KQ110 Human 7376 Details Get a Quote
RPS6KB2 Knockout HEK293 Cell Line EDJ-KQ125 Human 6199 Details Get a Quote
SMAD6 Knockout HEK293 Cell Line EDJ-KQ126 Human 4091 Details Get a Quote
JUN Knockout HEK293 Cell Line EDJ-KQ176 Human 3725 Details Get a Quote
JUN Knockout HEK293T Cell Line EDJ-KQ184 Human 3725 Details Get a Quote
ALKBH5 Knockout HEK293 Cell Line EDJ-KQ186 Human 54890 Details Get a Quote
Contact Us
*
*
*
How did you hear about us: