Choosing an MRD Assay
The Short Answer
Choose by what the assay detects: aberrant cells (flow), a known sequence (qPCR or digital PCR), or clonal rearrangements (NGS). Then check the failure modes, because each assay has one that produces a false negative.
Table 1. Assays Compared
| Assay | Detects | Typical sensitivity | Principal failure mode |
|---|---|---|---|
| Multiparameter flow | Cells with an aberrant phenotype | 10⁻⁴ to 10⁻⁵ | Panel and gating dependence; low cellularity samples |
| Allele-specific qPCR | One patient-specific sequence | 10⁻⁵ to 10⁻⁶ | Target lost to clonal evolution |
| NGS of rearrangements | Clonal immunoglobulin or receptor sequences | 10⁻⁵ to 10⁻⁶ | Requires a baseline reference; error-rate thresholds |
| Digital PCR | Absolute copies of a defined sequence | 10⁻⁴ to 10⁻⁵ | One target per assay; design effort |
Part 1 — Matching the Assay to the Question
A question about early response during induction is usually answered with flow, because it is fast and does not require a baseline. A question about deep remission or about a trial endpoint benefits from the higher sensitivity of a sequence-based assay, provided a baseline is available.
A question about clonal architecture is not an MRD question at all, and requires sequencing across multiple timepoints rather than a single assay result.
Part 2 — The Reporting Requirements
Every MRD result needs four accompanying items: the assay, its validated sensitivity, the sample's cellularity or input, and the baseline used. A negative result without those is uninterpretable, because it may reflect disease absence or assay failure.
Where two assays are used, report both. Concordance is informative, and discordance usually identifies either clonal evolution or a technical limitation, both of which matter for the conclusion.
Table 2. Reporting Checklist
| Item | Why |
|---|---|
| Assay and platform | Results are assay-specific |
| Validated sensitivity | A negative result means different things at 10⁻⁴ and 10⁻⁶ |
| Sample input and cellularity | Low input reduces sensitivity |
| Baseline reference | Required for sequence-based assays |
| Timepoint relative to treatment | MRD changes with therapy |
Part 3 — Where This Connects
The biology and the endpoint implications are in /leukemic-stem-cells-mrd, and the cluster framework is in /hematologic-malignancies. The clinical-assay side is in /companion-diagnostics-assay-selection.
Contact EDITGENE to request a project consultation or a quote.
Scientific scope and validation note
Thresholds and validated sensitivities are assay- and disease-specific, and a result below the validated range should not be reported as positive or negative without qualification.
Selected references for further reading
- • Heuser M, Freeman SD, Ossenkoppele GJ, et al. 2021 Update on MRD in acute myeloid leukemia: a consensus document from the European LeukemiaNet MRD Working Party. Blood. 2021;138:2758–2767.
- • Schuurhuis GJ, Heuser M, Freeman S, et al. Minimal/measurable residual disease in AML: a consensus document from the European LeukemiaNet MRD Working Party. Blood. 2018;131:1275–1291.
Scientific interpretation and experimental design
- • Choose the assay by what it detects, not by which is available.
- • Report the validated sensitivity and the sample input with every result.
- • Treat discordance between assays as information, not noise.
- • Re-test at progression; the baseline clone may no longer be present.
Related Services
Related Products
| Product name | Cat.No. | Species | Gene ID | |
|---|---|---|---|---|
| PBRM1 Knockout A-549 Cell Line | EDJ0001-K01 | Human | 55193 | Details Get a Quote |
| YTHDC1 Knockout A-549 Cell Line | EDC07652 | Human | 91746 | Details Get a Quote |
| TP53 Knockout HCT 116 Cell Line | EDC07854 | Human | 7157 | Details Get a Quote |
| Sirt2 Knockout MH-S Cell Line | EDJ-KQ78173 | Mouse | 64383 | Details Get a Quote |
| TFE3 Knockout KGN Cell Line | EDJ-KQ48 | Human | 7030 | Details Get a Quote |
| Stub1 Knockout MB49 Cell Line | EDJ-KQ53 | Mouse | 56424 | Details Get a Quote |
| ARID1A Knockout SNK-6 Cell Line | EDJ-KQ64 | Human | 8289 | Details Get a Quote |
| Tet1 Knockout Kupffer Cell Line | EDJ-KQ88 | Mouse | 52463 | Details Get a Quote |
| NR1H3 Knockout HEK293T Cell Line | EDJ-KQ109 | Human | 10062 | Details Get a Quote |
| NR1H2 Knockout HEK293T Cell Line | EDJ-KQ110 | Human | 7376 | Details Get a Quote |
| RPS6KB2 Knockout HEK293 Cell Line | EDJ-KQ125 | Human | 6199 | Details Get a Quote |
| SMAD6 Knockout HEK293 Cell Line | EDJ-KQ126 | Human | 4091 | Details Get a Quote |
| JUN Knockout HEK293 Cell Line | EDJ-KQ176 | Human | 3725 | Details Get a Quote |
| JUN Knockout HEK293T Cell Line | EDJ-KQ184 | Human | 3725 | Details Get a Quote |
| ALKBH5 Knockout HEK293 Cell Line | EDJ-KQ186 | Human | 54890 | Details Get a Quote |
- 1
- 2
- ...
- Next Page »